Circular July 2008
2 (two) Sets 56 MW each
Originally Dual fuel, liquid side removed but
available NEW 1985
NOTE: STEAM TURBINE FAILED AND THE PLANT BECAME
INEFFICIENT.
2 -56,000 KW 80% PF 70,000 KVA BBC GENERATORS, 3 PHASE,
60 CYCLE, 13,800 VOLTS, 3600 RPM, DIRECT CONNECTED TO
2 - 56,000 KW BBC GAS TURBINES , NATURAL GAS FIRED,
( liquid fuel items available site ) TYPE 8, 3600 RPM. NEW
1985.
Each unit is equipped with
400,400#/HR heat recovery steam generator available at additional cost.
Please note that these units located in the United
States were operated at 60 cycle - 13,800 volts
Gas Turbine
Manufacturer
BBC Type 8
Type
8 Axial Reaction
Number of
Compressor Stages 12
Number of
Shafts
1 Common
Number of Turbine Stages 3
Speed of
Shaft
6339/6349
Mechanical Limit
56 MW
Exhaust Mass
Flow
177 kg/s
Exhaust Gas
Temp
525C
Casing
Design
Horizontal Split
Rotor
Design
welded
Number of Journel Bearings 2
Number of Thrust Bearings 1
Combustion Chamber
Manufacturer
BBC
Tile
Temp
820C
Pressure
Drop
3,7%
External
Diameter
1.95Meters
Reduction Gear
Manufacturer
MAAG
Type
G-72 S
Generator
Manufacturer
BBC
Type
WY 16 L0068 LLT
Frequency
50/60
Nominal
Output
68.75/82.5 MVA
Rated
Voltage
11.5/13.8 kV
Voltage
range
+/- 5%
Rated
Current
3452/3600 A
Speed
3000 rpm
Short Circuit
ratio
0.456 kc
Exciter
Manufacturer
BBC
Type
WBF 6-4 K
Frequency
50/60 Hz
1. Last overhaul, GT-901 - March 2000,
GT-902 - November 2000.
2. GT-901 Overhaul
March 2000:
Replaced all hot gas path parts
Replaced hot gas casing
Cleaned and inspected compressor
blades, reshimmed rows 10, 11, & 12
Repaired tile carrier to specifications
Replaced 13 row A tiles, 4 row B tiles, 0
row C
Removed liquid fuel oil system
Rebuilt all 3 blow-off valves
Completed alignment inspection, did not
move
Inspected gearbox, combustor inner liner
insert (CILI), rotor, bearings, and generator
I&E calibrated/checked all alarms and
trips, modified control system for the fuel oil system
removal, pressure tested the gas system, calibrated gas control valve, rotor
end face and compressor
discharge temperature transmitter, and the turbine inlet temperature
controller.
GT-902 Overhaul November
2000
Replaced all hot gas
path parts
Replaced tile carrier with spare from
Shell unit
Cleaned and inspected compressor blades
Replaced 33 row A tiles, 39 row B tiles,
43 row C tiles
Removed liquid fuel oil system
Completed alignment inspection, moved
gearbox, generator
Inspected gearbox, hot gas casing,
combustor inner liner insert (CILI), rotor, bearings, and generator
Rebuilt all 3 blow-off valves
I&E calibrated/checked all alarms and
trips, modified control system for the fuel oil system removal,
pressure tested the gas system, calibrated gas control valve, rotor end face
and compressor
discharge temperature transmitter, and the turbine inlet temperature controller
3. Operating hours since
last OH:
GT-91 - 26,275 OH, 29,395 EOH,
GT-92 - 23,475 OH, 26,375 EOH
Equipment may be in need of an overhaul. BUT
RUNNING WHEN SHUT DOWN
Please note that these units located in the USA were
operated at 60 cycle - 13,800 volts
Both Plants must be purchased , a Heat recovery
is also available with each Turbine.
Note: The heat rate on these turbines are as good as
the newer high temp Turbines.
These were originally 50 hz, with reduction gear
modification for 60 hz, could go back.
Price is 5.25 Million USD each
HRSG is needed @ $400,000
each
Gear modification to 50 hz expected @
$450,000
For more information ask by Email
SCOPE and PICTURES on request
11.) 4 each
GE Frame 5-la Gas Turbines,
less than 1,000
hours since last major overhaul
TURBINE DATA
BRAND
GE
MODEL
MS5001 LA
CAPACITY
16.5 MW
RPM
5100
CONTROLS
WDPF
MHZ
FLOATING POINT CENTRAL PROCESSOR
ELECTRICAL
FULL UTILITY
ELECTRICAL, WITH METERING, RELAYS ETC.
SYNCH EQUIPMENT FACTORY,
AUTOMATIC :: AUTO SYNCHRONIZER
EXHAUST SYSTEM FACTORY
COMPLETE
RPM
5100
STAGES:
15
EXHAUST GAS FLOW 255.5 LB/SEC
AIR
INTAKE
INCLUDED
HUMIDITY
83%

TEMP
28 c
AREA FOR
TURBINE
565 METERS
TEMP
964 f
AIR @ COMPRESSOR
86 f
NO. OF
COMBUSTION 10
COOLING
FIN / FAN
GENERATOR
GENERATOR
GE
MODEL
ATB
INSULATION
CLASS F
COOLED
AIR
PF
0.8
CAPACITY
20780 KVA
CYCLE
60 HZ
VOLTAGE
13.8KV
AMPS
788 AMPS
EXCITER
RPM
3600
POLES
2
POLES
AUXILIARY POWER FROM
STATION TRANSFORMER , WITHIN UNIT
STARTING
BLACK START DIESEL ( one per group )
WEIGHTS : GENERATOR :::: 147,800 LB’S
TURBINE :::: 176,000 LB’S
Price 3.45 Million USD each
SCOPE and PICTURES on request
For more information ask by Email
Best regards
CH Non-Food Import-Export Corporation
Peter Pressmar (CEO)
Skype: peterpressmar
British Virgin Islands
Phone: +1 206-201-2420
Fax: +1 206-337-0754
Phone Brazil: +55 21 3521-7225
mailto:office6@ch-non-food.com
http://www.ch-non-food.com/